QUEMADORES ECOFLAM

MAX
Light oil
Monoblock burners from 17 to 546 kW
• New control box Thermowatt allowing to improve the interface with service personnel; the digital display (PAB versions) featuring the interactive language with pictograms gives real time information about burner operation and statistics stored during the heating season
• High efficiency fan ventilation system (HPV) allowing easy matching with boilers having high combustion chamber back pressure
• Electrical wiring simple to disassemble for easy maintenance
• Combustion head easy to assemble and adjust for fine set up
• Single bolt burner fixing with the possibility to firmly secure it to the flange in three different positions for easier maintenance
• Air damper with progressive micrometric air regulation adjustable in three positions
• Monoblock electrodes for easy and steady installation into the nozzle even after maintenance
• Low NOx version class 3 with yellow flame developed by Ecoflam
• Selected models are available in HT version and with “D” pump for light oil with viscosity up to 200 cTs
• The hinge flange allows accessibility to burner head without losing burner settings
• MAX 1 ÷ 12 work with electrical frequency 50-60 Hz
MAX range

One stage low NOx class 3 (NOx <120 mg/kWh) - B10 |
Output (kW) |
17,6 ... 35,5 |
|
22,5 ... 47,4 |
|
|
|
One stage class 2 (NOx <185 mg/kWh) - B10 |
Output (kW) |
17,6 ... 41,4 |
|
20 ... 59 |
|
47 ... 105 |
|
60 ... 130 |
|
73,4 ... 190 |
|
86,4 ... 237 |
|
110 ... 319 |
|
|
|
One stage with pre-heater (NOx <185mg/kWh) - B10 |
Output (kW) |
20 ... 39 |
|
20 ... 59 |
|
|
|
Two stages class 2 (NOx <185 mg/kWh) |
Output (kW) |
166 ... 427 |
|
202 ... 546 |
|
|
|
Two stages hydraulic system class 2 (NOx <185 mg/kWh) - B10 |
Output (kW) |
60 ... 130 |
|
77 ... 190 |
|
102 ... 300 |
|
166 ... 427 |
|
202 ... 546 |
MAIOR
Light oil
Monoblock burners from 415 to 17000 kW

Main features
• All burners feature high versatility on different types of domestic, commercial and industrial application
• Aluminium casing up to MAIOR P 200.1 and steel casing from P 300.1 with electrical panel on board
• Two stages with hydraulic or electric servomotor up to MAIOR P 400.1
• Progressive mechanical version with flow return nozzle. Shut down flow system on the nozzle managed by coil from MAIOR P 700.1
• Adjustable combustion head for fine-tune regulation and matching with different combustion chamber
• Modulating version with PID system controller with digital set point display and real time value
• Ecoflam offers the electronic range with BMS from the output of 2 MW up 17 MW in monoblock and up to 25 MW in duoblock configuration with electrical panel assembled into the burner or on request with separate switch cabinet
MAIOR range
Two stages hydraulic system |
Output (kW) |
415 ... 710 |
|
474 ... 949 |
|
830 ... 1423 |
|
592 ... 1780 |
|
710 ... 2372 |
|
1000 ... 3000 |
|
1300 ... 3900 |
|
|
|
Two stages |
Output (kW) |
415 ... 710 |
|
474 ... 949 |
|
830 ... 1423 |
|
592 ... 1780 |
|
710 ... 2372 |
|
1000 ... 3000 |
|
1300 ... 3900 |
|
|
|
Two stages progressive mechanical |
Output (kW) |
296 ... 532 |
|
415 ... 710 |
|
474 ... 949 |
|
830 ... 1423 |
|
592 ... 1780 |
|
710 ... 2372 |
|
1000 ... 3000 |
|
1300 ... 3900 |
|
1578 ... 5000 |
|
1795 ... 5800 |
|
2417 ... 7500 |
|
2750 ... 8500 |
|
3300 ... 10500 |
|
4367 ... 12500 |
|
5000 ... 15000 |
|
5700 ... 17000 |
• DUOBLOCK and ELECTRONIC versions are available (from 2 to 25 MW) on request for selected output to match main boilers and industry applications
MAXFLAM - OILFLAM
Heavy oil
Monoblock burners from 68 to 17000 kW

Main features
• MAXFLAM and OILFLAM range work with heavy oil up to 50°E at 50°C with On/Off switch to exclude the circuit heaters in order to operate also with low viscosity heavy oil
• All burners feature high versatility on different types of domestic, commercial and industrial application
• Aluminium casing up to OILFLAM 200.1 with electrical panel integrated. Steel casing from 300.1 with electrical cabinet integrated or in loosen form. All burners complete with pre heater management system
• Adjustable combustion head for fine-tune regulation and matching with different combustion chamber
• Two stages version available with electric servomotor with two nozzles from MAXFLAM 30 up to OILFLAM 400.1
• Progressive or modulating nozzle with flow return. Shut down flow system on the nozzle controlled by coil from OILFLAM 300.1
• Digital thermo regulator “GEFRAN” integrated on the front panel for granting the temperature stability of the oil fuel from OILFLAM 300.1
• Self-cleaning filter installed in the pre-heater in order to keep the nozzle clean from OILFLAM 300.1
• Ring system for oil preparation can be designed and supply on request
MAXFLAM range
One stage - 50°E fuel viscosity at 50°C |
Output (kW) |
68 ... 136 |
|
108 ... 227 |
|
170 ... 340 |
|
|
|
Two stages - 50°E fuel viscosity at 50°C |
Output (kW) |
205 ... 410 |
|
205 ... 570 |
OILFLAM range
Two stages - 50°E fuel viscosity at 50°C |
Output (kW) |
464 ... 930 |
|
682 ... 1395 |
|
682 ... 1700 |
|
682 ... 2093 |
|
1000 ... 3000 |
|
1300 ... 3900 |
|
|
|
Two stages progressive mechanical - 50°E fuel viscosity at 50°C |
Output(kW) |
464 ... 930 |
|
682 ... 1395 |
|
682 ... 1700 |
|
682 ... 2093 |
|
1000 ... 3000 |
|
1300 ... 3900 |
|
1578 ... 5000 |
|
1795 ... 5800 |
|
2417 ... 7500 |
|
2750 ... 8500 |
|
3300 ... 10500 |
|
4367 ... 12500 |
|
5000 ... 15000 |
|
5700 ... 17000 |
MAXFLAM - OILFLAM
Heavy oil
Monoblock burners from 68 to 17000 kW

Main features
• MAXFLAM and OILFLAM range work with heavy oil up to 50°E at 50°C with On/Off switch to exclude the circuit heaters in order to operate also with low viscosity heavy oil
• All burners feature high versatility on different types of domestic, commercial and industrial application
• Aluminium casing up to OILFLAM 200.1 with electrical panel integrated. Steel casing from 300.1 with electrical cabinet integrated or in loosen form. All burners complete with pre heater management system
• Adjustable combustion head for fine-tune regulation and matching with different combustion chamber
• Two stages version available with electric servomotor with two nozzles from MAXFLAM 30 up to OILFLAM 400.1
• Progressive or modulating nozzle with flow return. Shut down flow system on the nozzle controlled by coil from OILFLAM 300.1
• Digital thermo regulator “GEFRAN” integrated on the front panel for granting the temperature stability of the oil fuel from OILFLAM 300.1
• Self-cleaning filter installed in the pre-heater in order to keep the nozzle clean from OILFLAM 300.1
• Ring system for oil preparation can be designed and supply on request
MAXFLAM range
One stage - 50°E fuel viscosity at 50°C |
Output (kW) |
68 ... 136 |
|
108 ... 227 |
|
170 ... 340 |
|
|
|
Two stages - 50°E fuel viscosity at 50°C |
Output (kW) |
205 ... 410 |
|
205 ... 570 |
OILFLAM range
Two stages - 50°E fuel viscosity at 50°C |
Output (kW) |
464 ... 930 |
|
682 ... 1395 |
|
682 ... 1700 |
|
682 ... 2093 |
|
1000 ... 3000 |
|
1300 ... 3900 |
|
|
|
Two stages progressive mechanical - 50°E fuel viscosity at 50°C |
Output(kW) |
464 ... 930 |
|
682 ... 1395 |
|
682 ... 1700 |
|
682 ... 2093 |
|
1000 ... 3000 |
|
1300 ... 3900 |
|
1578 ... 5000 |
|
1795 ... 5800 |
|
2417 ... 7500 |
|
2750 ... 8500 |
|
3300 ... 10500 |
|
4367 ... 12500 |
|
5000 ... 15000 |
|
5700 ... 17000 |
MAX GAS
Gas
Monoblock burners from 17 to 500 kW

Main features
• New control box Thermowatt allowing to improve the interface with service personnel. The digital display (PAB versions) featuring the interactive language with pictograms gives real time information about burner operation and statistics stored during the heating season
• High efficiency fan ventilation system (HPV) allowing easy matching with boilers having high combustion chamber pressure
• Combustion head easy to assemble and adjust for fine set up
• Single bolt burner fixing with the possibility to firmly secure it to the flange in three different positions for easy maintenance
• Separate gas train (available for different inlet gas pressure) easy to assemble into the burner
• The hinge flange allows accessibility to burner head without losing burner settings
MAX GAS range
One stage Low NOx class 3 (NOx <80 mg/kWh) |
Output (kW) |
17 ... 48 |
|
34 ... 70 |
|
49 ... 108 |
|
40 ... 120 |
|
55 ... 175 |
|
55 ... 240 |
|
200 ... 350 |
|
232 ... 500 |
|
|
|
Two stages Low NOx class 3 (NOx <80 mg/kWh) |
Output (kW) |
40 ... 120 |
|
55 ... 175 |
|
55 ... 240 |
|
100 ... 350 |
|
120 ... 500 |
|
|
|
Two stages progressive mechanical Low NOx class 3 (NOx <80 mg/kWh) |
Output (kW) |
100 ... 350 |
|
120 ... 500 |
BLU
Gas
Monoblock burners from 270 to 17000 kW

Main features
• All burners feature high versatility on different types of domestic, commercial and industrial application
• Aluminium casing up to BLU 2000.1 and steel casing from 3000.1 with electrical panel IP40 on board
• Adjustable combustion head for fine-tune regulation and matching with different combustion chamber
• Modulating version with PID system controller with digital set point display and real time value
• Separate gas train (available for different inlet gas pressure) easy to assemble into the burner
• Configurated and special version on request for selected type of applications and fuel characteristics
BLU range
Two stages Low NOx class 3 (NOx < 80 mg/kWh) |
Output (kW) |
270 ... 700 |
|
280 ... 875 |
|
290 ... 1100 |
|
300 ... 1550 |
|
|
|
Two stages |
Output (kW) |
245 ... 970 |
|
260 ... 1200 |
|
342 ... 1770 |
|
414 ... 2150 |
|
|
|
Two stages progressive mechanical Low NOx class 3 (NOx < 80mg/kWh) |
Output (kW) |
270 ... 700 |
|
280 ... 875 |
|
290 ... 1100 |
|
300 ... 1550 |
|
|
|
Two stages progressive mechanical |
Output (kW) |
245 ... 970 |
|
260 ... 1200 |
|
342 ... 1770 |
|
414 ... 2150 |
|
630 ... 3000 |
|
875 ... 3900 |
|
1200 ... 5000 |
|
1500 ... 5800 |
|
1500 ... 7500 |
|
2000 ... 8500 |
|
2500 ... 10500 |
|
2700 ... 13000 |
|
3690 ... 15000 |
|
4000 ... 17000 |
MULTICALOR
Dual fuel (gas/light oil)
Monoblock burners from 120 to 17000 kW

Main features
• Aluminium casing up to MULTICALOR 200.1 and steel casing from 300.1 with electrical panel integrated on board
• Adjustable combustion head for fine-tune regulation and matching with different combustion chamber
• Two stages version with electric servomotor and integrated system for the regulation of air gas and light oil with two nozzles from MULTICALOR 45 to MULTICALOR 200.1
• Progressive version with electrical servomotor and double adjustable mechanical cam that allows air gas/light oil fine tuning
• Progressive modulating nozzle with flow and return. Shut down flow system on the nozzle managed by coil from MULTICALOR 700.1
• Separate gas train (available for different inlet gas pressure) easy to assemble into the burner. Gas pilot included in the combustion head with separate supply line
• Configurated and special version on request for selected type of applications and fuel characteristics
• Standard version running on manual fuel selection mode and on request automatic fuel changeover. The automatic change over system can be triggered by gas pressure or by a timer
MULTICALOR range
Two stages gas / Two stages light oil |
Output (kW) |
120 ... 500 |
|
190 ... 700 |
|
200 ... 1000 |
|
250 ... 1300 |
|
342 ... 1770 |
|
414 ... 2150 |
|
|
|
Two stages progressive mechanical gas / Two stages light oil |
Output (kW) |
190 ... 700 |
|
200 ... 1000 |
|
250 ... 1300 |
|
342 ... 1770 |
|
414 ... 2150 |
|
|
|
Two stages progressive mechanical gas / Two stages progressive mechanical light oil |
Output (kW) |
630 ... 3000 |
|
875 ... 3900 |
|
1200 ... 5000 |
|
1500 ... 5800 |
|
1500 ... 7500 |
|
2000 ... 8500 |
|
2500 ... 10500 |
|
2700 ... 13000 |
|
3690 ... 15000 |
|
4000 ... 17000 |
MULTIFLAM
Dual fuel (gas/heavy oil)
Monoblock burners from 400 to 17000 kW

Main features
• Aluminium casing up to MULTIFLAM 200.1 and steel casing from 300.1 with electrical panel IP54 on board
• Adjustable combustion head for fine-tune regulation and matching with different combustion chamber
• Two stages version with electric servomotor and integrated system for the regulation of air gas and heavy oil with two nozzles for MULTIFLAM 200.1
• Progressive version with electrical servomotor and double adjustable mechanical cam that allows air gas/heavy oil fine tuning
• Progressive modulating nozzle with flow and return. Shut down flow system on the nozzle managed by coil from MULTIFLAM 700.1
• Digital thermo regulator “GEFRAN” integrated onthe front panel for granting the temperature stability of the oil fuel from MULTIFLAM 300.1
• Modulating version with PID system controller with digital set point display and real time value
• Separate gas train (available for different inlet gas pressure) easy to assemble into the burner. Gas pilot included in the combustion head with separate supply line
• Configurated and special version on request for selected type of applications and fuel characteristics
MULTIFLAM range
Two stage gas / Two stages heavy oil |
Output (kW) |
414 ... 2150 |
|
|
|
Two stages progressive mechanical gas / Two stages progressive mechanical heavy oil |
Output (kW) |
630 ... 3000 |
|
875 ... 3900 |
|
1200 ... 5000 |
|
1500 ... 5800 |
|
1500 ... 7500 |
|
2000 ... 8500 |
|
2500 ... 10500 |
|
2700 ... 13000 |
|
3690 ... 15000 |
|
4000 ... 17000 |